← SCANNER LAB

SIM B OF 10

Inversion Recovery: FLAIR & STIR

After a 180° inversion pulse, each tissue's magnetization recovers from negative through zero. Excite when a tissue crosses zero and it is nulled. Long TI nulls CSF (FLAIR); short TI nulls fat (STIR).

Acquiring…
APRL
Simulated image — educational phantom

Weighting

Inversion recovery (T1-weighted IR)

Scan time

1:26

Voxel

0.90 × 1.20 × 5 mm

TE used

110 ms

SNR (vs reference protocol)100%
SAR (of normal-mode limit)15%
Chemical shift: 1.4 pxPhase lines acquired: 192Slices per TR: 41

PROTOCOL

Anatomy

800 ms
9000 ms
110 ms

Field strength

Simulated case

MISSIONS

0/3 COMPLETE · IN ORDER
  1. Current mission: Null CSF to make a FLAIR+75 XP
  2. Locked: Null fat to make a STIR+75 XP

    LOCKED · COMPLETE THE MISSION ABOVE

  3. Locked: FLAIR at 3 T (the TI must change!)+100 XP

    LOCKED · COMPLETE THE MISSION ABOVE

Recovery after the 180° inversion — tissues crossing zero at TI are nulled

time after inversion (ms)MzTI 800
CSFGray matterWhite matterFat
  • CSF null ≈ 2372 ms
  • Gray matter null ≈ 762 ms
  • White matter null ≈ 451 ms
  • Fat null ≈ 180 ms